Skip to main content

Market analysis of 8 November 2026

Hourly clean-energy matching connects each hour of demand to the eligible supply that serves it. Network Map combines the physical dispatch result with an entered matching policy, so a project study can follow solar energy directly to load and through storage.

Network Map infrastructure view used as geographic context for Hourly Clean-Energy Matching: Follow Solar Through Storage.
Network Map infrastructure context for clean-energy matching studies.

Set The Physical Case And Matching Policy

This saved modelled run was completed on 8 November 2026. It uses a supplied four-hour profile from 00:00 to 04:00 UTC on 1 January 2026. The entered system has 1 kW of solar, a 0.5 kW / 1 kWh battery and 0.5 kWh of demand in each hour.

The battery starts and finishes empty. The caller supplies 100% charging and discharging efficiencies for this worked example. The matching policy treats solar as eligible and retains its attributes through storage, using caller-attested ownership. The selected policy matches physical energy with retained attributes.

Follow Solar Directly And Through Storage

In each of the first two hours, the model produces 1 kWh of solar energy. Half serves load directly and half charges the battery. The battery reaches 1 kWh at 02:00 UTC. It then supplies 0.5 kWh in each of the final two hours.

Solar Reaches Load By Two Paths. Modelled run · 1 January 2026 · UTC. kWh per hour.
Modelled run · 1 January 2026 · UTC. Each hour has 0.5 kWh demand and 0.5 kWh matched supply under the entered retained-attribute policy.

Explore Network Map

The returned path ledger preserves the solar source through the storage cycle. Summing the paths to served load gives 1 kWh of direct solar and 1 kWh of stored solar across the study window. Energy entering storage is counted at charging; its later delivery is traced to load in the matching result.

Stored Solar Moves Across The Hours. Modelled run · 1 January 2026 · UTC. Battery energy · kWh.
Modelled run · 1 January 2026 · UTC. Caller-supplied charging and discharging efficiencies: 100%. Initial and terminal inventory: 0 kWh.

Read The Hourly Result

The result matches 0.5 kWh of demand in every hour. Total matched energy is 2 kWh against 2 kWh of demand: 100% modelled hourly matching over this four-hour example. The hourly rows and source audit make the total traceable to the underlying dispatch, storage inventory and caller-defined policy.

Use the same workflow with your project profiles, storage settings and ownership evidence. Review both the hourly result and the energy paths to understand when eligible supply reaches demand. The Options, Results And Exports guide explains the result workflow, and Project Modelling provides the wider study context.

Start Your Project Study