Docs Menu
Single-Line Diagrams and Engineering
Inspect a diagram from loaded map layers and import its displayed scope into an editable engineering circuit.
Build a Map Diagram
Single-Line Diagram requires Professional or Enterprise access.
- Move the map to the area you want to inspect.
- Load detailed layers for the relevant assets. Use Load detailed layer or Autoload Details.
- Set any layer filters before opening the diagram.
- Choose the Single-Line Diagram button in the map toolbar on the right.
- Read the scope and exclusion notes beside the diagram.
The diagram covers the current map view, not one substation. It draws the assets of all loaded detailed layers that are in the view. The header shows the node and link counts. A note says how many assets are shown and how many are outside the view. In this example, transmission stations show as TRANSFORMER nodes and lines show as LINE nodes.

The diagram uses detailed layers loaded on the map. It does not download a complete electrical network model. The displayed scope follows the map view and active filters. Low-voltage line exclusions and other limits are reported with the captured scope.
If No assets available for the diagram appears, return to the map, load detailed layers for that area, and open the diagram again.
Inspect and Arrange the Diagram
- Click a node to inspect its simplified asset details.
- Read available Name, Type, Stage, Asset ID, Layer, Layer Type, Voltage, Capacity, and Status values.
- Use Clear selection to clear the selected asset.
- Drag nodes to change the diagram layout. This changes the drawing, not the source asset.
- Use Zoom in, Zoom out, Fit diagram, and Reset zoom to navigate.
- Use Map, with the tooltip Back to map, to return to the map.
The diagram has display limits of 420 nodes and 720 links. It scans up to 8,000 source assets and renders up to 180 link labels. These are display and safety limits, not statements that the surrounding network is complete. A scope count can be a lower bound if a scan was capped.
For a more complete local scope, narrow the map area or filters and capture again. Load more detailed layers if the required assets are absent.
Open the Diagram in Grid Circuit Builder
The side panel of the diagram has Open in Grid Circuit Builder. The app says it Creates an unsaved Engineering Studies circuit draft from exactly this displayed diagram.
- Select Open in Grid Circuit Builder. You can also use Import > Current Single-Line Diagram inside the builder.
- Select an editable engineering project if needed.
- Review the preview counts, source layers, map extent, filters, and exclusions.
- Select Create unsaved draft for a complete displayed capture, or Create Best-Estimate when the capture reports incomplete scope.
- Review the new circuit in Grid Circuit Builder.
- Save a revision to preserve the draft.
The import transfers the displayed diagram, including its reviewed scope and provenance. It does not silently include assets that were not displayed. Cancel leaves the preview without creating the new draft.
Understand the Preview
| Preview item | Meaning |
|---|---|
| components | Assets represented in the displayed capture. |
| explicit links | Links derived from explicit source relationships. |
| model-inferred links | Candidate links inferred while constructing the network diagram. |
| UI-synthetic links | Candidate links added by the display layout. |
| hydration failures | Source identities that could not be resolved cleanly, including missing, duplicate, stale, or mismatched records. |
| unmapped types | Assets that still need an explicit equipment type. |
| missing parameters | Required electrical fields absent from the captured asset data. |
| incomplete | The capture contains exclusions, truncation, or other scope limits. Review them before publication. |
Reviewed source layers shows displayed, matching, and total counts where available. Active layer filters records the filters used. Limits and reconciliation identifies omitted data and scope limits. An estimated map extent is labeled as estimated.
Turn the Draft into a Study Model
- Map unknown equipment types.
- Check each inferred link. Confirm it, reconnect it, or remove it.
- Review equipment terminal sides and connected bus voltages.
- Supply missing electrical values and confirm suggested values by editing them.
- Resolve source-reference and scope issues in Import reconciliation.
- Save and publish the revision after validation passes.
- For a supported study type, open Setup & Run, select Circuit Revision, and choose Published circuit revision.
An incomplete capture may be saved as a draft. Scope limitations must be resolved or explicitly accepted as a narrowed scope before publication and study use. Accepting a narrowed scope does not restore omitted assets.
Related Guides
- Grid Circuit Builder
- Network Model Import and Validation
- Grid Circuit Element Reference
- Running Engineering Studies
- Engineering Exports and Handoffs